80 Plus (trademarked 80 PLUS) is a voluntary certification program launched in 2004, intended to promote efficient energy use in computer power supply units (PSUs).


Certification is acquirable for products that have more than 80% energy efficiency at 20%, 50% and 100% of rated load, and a power factor of 0.9 or greater at 100% load.
History
Summarize
Perspective
- EPRI (Electric Power Research Institute) and Ecos Consulting (promoter of the brand) develop the Generalized Internal Power Supply Efficiency Test Protocol for desktop derived multi-output power supplies.
- March 2004: the 80 Plus idea was presented as an initiative at the ACEEE Market Transformation Symposium.
- February 2005: the first market-ready power supply was created by Seasonic.
- 2006: Energy Star added 80 Plus requirements to their then-upcoming (in effect since July 2007) Energy Star 4.0 computer specifications.
- November and February 2006: HP and Dell certify their PSUs to the 80 Plus specification.
- 20 July 2007: Energy Star Computer Specification 4.0 goes into effect. The specification includes 80 Plus power supply efficiency levels for desktop computers.
- December 2007: over 200[1] PSUs on the market are 80 Plus certified and it is becoming the market standard.
- First-quarter 2008: standards revised to add Bronze, Silver, and Gold higher efficiency level certifications.
- October 2009: added specification for the Platinum efficiency level.[2]
- February 2012: Dell and Delta Electronics working together were able to achieve world-first 80 Plus Titanium server power supply.[3]
Use by related initiatives
The Climate Savers Computing Initiative efficiency level targets for workstations for 2007 through 2011, corresponding to the 80 Plus certification levels. From July 2007 through June 2008, the basic 80 Plus level (Energy Star 4.0). For the next year, the target is 80 Plus Bronze level, the following year 80 Plus Silver, then 80 Plus Gold, and finally Platinum.
Remove ads
Efficiency level certifications
Summarize
Perspective
As of 2025 there are six categories for the certification:
- 115V Internal: certified for desktop, workstation and non-redundant server applications.
- 115V Industrial: Units in any physical format (embedded, encapsulated, open frame, rack mount, DIN-mount).
- 230V EU Internal Non-Redundant: certified for redundant, data center applications.
- 230V Internal Redundant: certified for desktop, workstation and server applications in non-redundant configurations.
- 277V/480V Internal: certified for redundant, data center applications.
- 380V DC Internal Redundant: certified for redundant, data center applications.
For the higher certification levels, the requirement of 0.9 or better power factor was extended to apply to 20% and 50% load levels, as well as at 100% load. The Platinum level requires 0.95 or better power factor for servers.[4] Redundancy is typically used in data centers.
Remove ads
Certification
Summarize
Perspective

Plug Load Solutions tests PSUs according to their testing protocol[7] and lists certified PSUs with downloadable certificates in PDF format,[8] allowing consumers to verify how many and which models are listed by each company.
Misleading power supply advertising
There have been instances where companies claim or imply that their supplies are 80 Plus when they have not been certified, and in some cases do not meet the requirements.[9][10] For example, the highest 80 Plus is 80+ Titanium (95.4% efficiency at 50% load).[7] Some companies will claim they meet this requirement even when they are only close (i.e. 94.xx%) therefore claiming 80+ Titanium.[11] However, this is not the case as one could easily modify the test unit to be more enhanced than production models in order to slightly raise numbers.[12]
When a company resells an OEM power supply under a new name, it must be certified under the new name and company, even if the OEM supply is certified. In some instances, a reseller has claimed a higher wattage than the supply can deliver, so the resellers' supply would not meet 80 Plus requirements.[9]
Although some power supply manufacturers name their products with similar names, such as "85 Plus", "90 Plus" and "95 Plus",[13][14] there is no such official certification or standard.
Technical overview
Summarize
Perspective
The efficiency of a computer power supply is its output power divided by its input power; the remaining input power is converted to heat as expected under conservation of energy. For instance, a 600 W power supply with 60% efficiency running at full load would draw 1000 W from the mains and waste 400 W as heat.
600 W output
400 W heat
|
|
1000 W input
|
|
A 600 W power supply with 80% efficiency running at full load would draw 750 W from the mains and waste only 150 W as heat.
600 W output
150 W heat
|
|
750 W input
|
|

For a given power supply, efficiency varies depending on how much power is being delivered. Supplies are typically most efficient at between half and three-quarters load, much less efficient at low load, and somewhat less efficient at maximum load. Older ATX power supplies were typically 60% to 75% efficient. To qualify for 80 Plus, a power supply must achieve at least 80% efficiency at three specified loads (20%, 50% and 100% of maximum rated power). However, 80 Plus supplies may still be less than 80% efficient at lower loads. For instance, an 80 Plus, 520 watt supply could still be 70% or less efficient at 60 watts (a typical idle power for a desktop computer).[15] Thus it is still important to select a supply with capacity appropriate to the device being powered.
It is easier to achieve the higher efficiency levels for higher wattage supplies, so gold and platinum supplies may be less available in consumer-level supplies of reasonable capacity for typical desktop machines.
Typical computer power supplies may have power factors as low as 0.5 to 0.6.[16] The higher power factor reduces the peak current draw, reducing load on the circuit or on an uninterruptible power supply.
Reducing the heat output of the computer helps reduce noise, since fans do not have to spin as fast to cool the computer. Reduced heat and resulting in lower cooling demands may increase computer reliability.[16]
Remove ads
Shortcomings
Summarize
Perspective
Thermal conditions at full load
The testing conditions may give an unrealistic expectation of efficiency for heavily loaded, high power (rated much larger than 300 W) supplies. A heavily loaded power supply and the computer it is powering generate significant amounts of heat, which may raise the power supply temperature, which is likely to decrease its efficiency. Since power supplies are certified at room temperature, this effect is not taken into account.[4][17]
Technically speaking, 80 Plus does test the power supply at full load, under which it is affected by its own heat generation. What it does not test is the effects of the heat generated by other components in the computer making its way into the power supply. There are additional requirements on testing PSUs with cooling fans, which draw power and reduce the measured efficiency. PSUs with no fan or an always-on, fixed-speed fan can be tested directly. PSUs with an internally-controlled fan must undergo a warmup period of 30 minutes or five fan cycles. PSUs with an externally-controlled fan should be tested at minimum fan speed setting.[18]: 18
Standby and very low load
80 Plus does not set efficiency targets for very low load. For instance, generation of standby power may still be relatively inefficient, and may not meet requirements of the One Watt Initiative. Testing of 80 Plus power supplies shows that they vary considerably in standby efficiency. Some power supplies consume half a watt[19] or less in standby with no load, where others consume several times as much at standby,[20] even though they may meet higher 80 Plus certification requirement levels.
The 80 Plus Titanium level expands requirements to include efficiency at 10% load. The 80 Plus Ruby level additionally includes efficiency at 5% load. See tables above for precise requirements.
The 80 Plus measurement protocol includes the measurement of standby power, but it is not stated anywhere on their webpage whether it is taken account into certification.[18]