The Lee–Kesler method [1] allows the estimation of the saturated vapor pressure at a given temperature for all components for which the critical pressure Pc, the critical temperature Tc, and the acentric factor ω are known.

Equations

Summarize
Perspective

with

(reduced pressure) and (reduced temperature).
Remove ads

Typical errors

The prediction error can be up to 10% for polar components and small pressures and the calculated pressure is typically too low. For pressures above 1 bar, that means, above the normal boiling point, the typical errors are below 2%. [2]

Example calculation

For benzene with

  • Tc = 562.12 K[3]
  • Pc = 4898 kPa[3]
  • Tb = 353.15 K[4]
  • ω = 0.2120[5]

the following calculation for T = Tb results:

  • Tr = 353.15 / 562.12 = 0.628247
  • f(0) = −3.167428
  • f(1) = −3.429560
  • Pr = exp( f(0) + ω f(1) ) = 0.020354
  • P = Pr · Pc = 99.69 kPa

The correct result would be P = 101.325 kPa, the normal (atmospheric) pressure. The deviation is −1.63 kPa or −1.61 %.

It is important to use the same absolute units for T and Tc as well as for P and Pc. The unit system used (K or R for T) is irrelevant because of the usage of the reduced values Tr and Pr.