Top Qs
Timeline
Chat
Perspective

SAF-TE

Computer storage enclosure industry standard From Wikipedia, the free encyclopedia

Remove ads

In computer storage, SAF-TE (abbreviated from SCSI Accessed Fault-Tolerant Enclosure) is an industry standard to interface an enclosure in-band to a (parallel) SCSI subsystem in order to gain access to information or control for various elements and parameters. These include temperature, fan status, slot status (populated/empty), door status, power supplies, alarms, and indicators (e.g. LEDs, LCDs).[1] Practically, any given SAF-TE device will only support a subset of all possible sensors or controls.[2]

Remove ads

Scope

Thumb
A SCSI backplane with SCA-2 connectors inside an enclosure (SAF-TE device not visible)

Many RAID controllers can utilize a SAF-TE "activated" backplane by detecting a swapped drive (after a defect) and automatically starting a rebuild. A passive subsystem usually requires a manual rescan and rebuild.

A SAF-TE device (SEP) is represented as a SCSI processor device that is polled every few seconds by e.g. the RAID controller software.[1] Due to the low overhead required, impact on bus performance is negligible.[3] For SAS or Fibre Channel systems, SAF-TE is replaced by the more standardized SCSI Enclosure Services (SES).

The most widely used version was defined in the SAF-TE Interface Specification Intermediate Review R041497, released on April 14, 1997 by nStor (now part of Seagate Technology) and Intel.

Remove ads

Command interface

Summarize
Perspective

Status requests are performed as READ BUFFER SCSI commands, enclosure action requests as WRITE BUFFER commands.[2]

More information Command type, Opcode ...
Remove ads

See also

References

Loading related searches...

Wikiwand - on

Seamless Wikipedia browsing. On steroids.

Remove ads